Electric Cooktop
E30EC70FSS
planning
information
For 30" model:
E30EC70FSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
Granite Countertop
Installation Kit
PN # 903061-9010
52
cooking
Electric Cooktops
13"
max.
cabinet
depth
1
/
" min. recommended
1
2
distance between rear
4"x 8" opening to route
edge of cutout and
armored cable
nearest combustible
surface above countertop
20
/
" min.
1
8
20
/
" max.
1
4
25"min.
24"
2
1
/
" min. from edge of cutout
2
to front edge of countertop
Installation Specifications
Product Weight – 42 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts =
7.8 / 5.9 kW
Amps @ 240 / 208 Volts = 33.0 / 29.0 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Allow 2" space below armored cable opening to clear
electrical cable and allow space for installation of junction
box on wall at back of cooktop.
Overhead cabinetry should not exceed a 13" max. depth.
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be
no less than maximum width of appliance.
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
30
/
"
3
4
21
1
/
"
2
30
/
"
3
4
10"
5" min.
12"
Approximate location
of junction box
Allow 1-1/2" minimum clearance between rear edge
of cutout and nearest combustible surface above
countertop.
Allow 7-1/2" minimum clearance from edge of cooktop
to nearest combustible wall on either side of unit.
Drawers not recommended beneath cooktop.
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 5" beyond bottom of cabinets.
Combination Installations
For installation details refer to Project Planning Section.
Cooktop model E30EC70FSS is approved to be used
over any Electrolux ICON
Electric Cooktop Installation Over 30" Electric Single Wall
Oven Specifications page.)
Cooktop model E30EC70FSS is approved to be used
in combination with an Electrolux ICON
Vent. (Refer to Drop-In Cooktop / Downdraft Vent
Countertop Preparation page for detailed installation
specifications.)
30" min. for
unprotected cabinet
24" min. for
protected surface
5"
18"
min.
7
/
" min. to nearest
1
2
combustible wall
(either side of unit)
29
/
" min.
7
8
30" max.
®
Single Wall Oven. (Refer to
®