Master-Reset Selection - Extron electronics CrossPoint 450 Plus Series User Manual

Large scale matrix switchers
Hide thumbs Also See for CrossPoint 450 Plus Series:
Table of Contents

Advertisement

Figure 5-11 — Ties shown as crosspoints
Frequency read options (systems with a CrossPoint 450 Plus sync BME only) —
Allows you to set the input signal detection (DSVP) feature as follows:
To never sample and display the sync or no sync status
(set this option to None)
To automatically refresh the display
(set this option to Automatically every 10 seconds)
To sample the sync and update the display whenever you make a
confi guration change (set this option to On demand or by refresh).
Limit ties to same group — Allows you to limit the creation of ties using the
program to inputs and outputs that are in the same group (similar to front
panel operation).
Icons in I/O boxes — Erases any numbers in the I/O boxes in the Control
Program window (fi gure 5-4). You can place icons in the boxes.
Numbers in I/O boxes — Erases any icons in the I/O boxes in the
Control Program window and fi lls each box with the associated
input or output number.
Catch FPC/others changes — When checked, sets the switcher to report all
confi guration and setting changes to the Remote RS-232/RS-422 or Ethernet
connection that turned this selection on. These reports allow the Matrix
Switcher Control Program to track the changes that occur in the switcher's
confi guration and settings, whether commanded via the front panel, the
RS-232/RS-422 port, or the Ethernet port.

Master-Reset selection

Master reset clears all ties and presets, all video and audio mutes, resets all I/O
grouping, sets all input audio levels to unity gain (+0 dB), and sets all output
volume levels to 100% (0 dB of attenuation).
N Master reset does not reset the Internet protocol (IP) settings.