Press and hold the Preset button for approximately 2 seconds until it blinks
2.
(fi gure 3-41).
2 seconds
PRESET
PRESET
Press and hold the Preset button until it blinks.
All input buttons with assigned presets light red.
If you then save the configuration to a lit preset number,
the configuration data at that preset location will be overwritten.
= Blinking button
Figure 3-41 — Enter Save Preset mode
3.
Press and release the input or output button for the desired preset
(fi gure 3-42).
Press and release the Input 1 button.
The button blinks red to indicate that this
preset number is selected but not saved.
1
2
3
4
17 18 19 20 21 22 23 24
= Blinking button
Figure 3-42 — Select the preset
4.
Press and release the Enter button (fi gure 3-43). The current confi guration is
now stored in the selected memory location.
Press the Enter button to
save the preset.
C O N T R O L
VIEW
ESC
ENTER
PRESET
The Enter and Preset
buttons return to unlit or
background illumination.
Figure 3-43 — Press the Enter button
CrossPoint 450 Plus and MAV Plus Switchers • Operation
5
6
7
8
9
25
I
N
All input buttons and output
buttons return to unlit or
background illumination.
Red
(Preset Assigned)
1
2
3
17 18 19
I
N
Unlit
(No Preset Assigned)
C O N T R O L
VIEW
ESC
ENTER
PRESET
The Enter button blinks to
indicate the need to save the
preset.
The Preset button continues
to blink.