Extron electronics CrossPoint 450 Plus Series User Manual page 74

Large scale matrix switchers
Hide thumbs Also See for CrossPoint 450 Plus Series:
Table of Contents

Advertisement

Operation, cont'd
Perform a soft reset of the switcher as follows:
1.
Press and hold
the Reset button.
Events Reset
Press and hold
the Reset button.
IP Settings
Reset
Press and hold
the Reset button.
Absolute
Reset
Figure 3-70 — Whole switcher and absolute resets
2.
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-44
Press and hold the Reset button until the Reset LED blinks once (events reset),
twice (system reset), or three times (absolute reset) (fi gure 3-70).
Rx
RESET
3 seconds
Rx
RESET
3 seconds
Rx
RESET
3 seconds
Release the Reset button and then immediately press and hold the button
until the LED fl ashes three times. Release the Reset button. Nothing happens
if the second momentary press does not occur within 1 second.
Release, then
immediately
press and hold.
1
Reset LED
flashes once.
RESET
RESET
Release, then
immediately
press and hold.
2
Reset LED
flashes twice.
RESET
RESET
Release, then
immediately
press and hold.
3
Reset LED
flashes three
times.
RESET
RESET
Release the
Reset button.
3
Reset LED
flashes three
times.
RESET
Release the
Reset button.
3
Reset LED
flashes three
times.
RESET
Release the
Reset button.
3
Reset LED
flashes three
times.
RESET

Advertisement