HP Surestore 64 - Director Switch User Manual page 91

Command line interface user's guide
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Output
The event log data are displayed as a table that includes the following properties.
Date/Time
The date and time when the event occurred.
Code
The event reason code.
Severity
The severity of the event. The values are:
Major—Unit operational (major failure).
Minor—Unit operational (minor failure).
Severe—Unit not operational. The causes are either the switch contains no
operational SBAR cards or the system shutdowns due to CTP thermal
threshold violations.
Info—Unit operational (information only).
FRU
The FRU and FRU position, where applicable.
Event Data
The 32-byte hexidecimal description of the event in words.
Output Example
The output from the show.eventLog command displays as follows.
Date/Time
Code
----------------
----
04/12/01
10:58A
375
04/12/01
09:58A
385
04/11/01
07:18P
395
Severity
FRU
Event Data
--------
-----
-----------------------------------
Major
CTP-0
00010203 04050607 08090A0B 0C0D0E0F
Severe
CTP-0
00010203 04050607 08090A0B 0C0D0E0F
Severe
CTP-0
00010203 04050607 08090A0B 0C0D0E0F
show
79