HP Surestore 64 - Director Switch User Manual page 107

Command line interface user's guide
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Output
The switch attributes data is displayed as a table that includes the following properties.
State
The state of the switch (for example, online or offline).
BB Credit
The BB credit as set in the config.switch.bbCredit command.
R_A_TOV
The R_A_TOV as set in the config.switch.raTov command.
E_D_TOV
The E_D_TOV as set in the config.switch.edTov command.
Preferred Domain Id The domain ID as set in the config.switch.domainId command.
Switch Priority
The switch priority as set in the config.switch.priority command.
Rerouting Delay
The rerouting delay as set in the config.switch.rerouteDelay command.
Operating Mode
The operating mode (Open Systems or S/390). This attribute cannot be
configured through the command line interface.
Interop Mode
The interoperability mode as set in the config.switch.interopMode command.
Active Domain Id
The active domain ID of the switch. This ID may or may not be the same as
the preferred domain ID.
World Wide Name
The world-wide name for the switch.
Output Example
The output from the show.switch command displays as follows.
Switch Information
State:
Online
BB Credit:
2
R_A_TOV:
20
E_D_TOV:
4
Preferred Domain Id: 1
Switch Priority:
Default
Rerouting Delay:
Enabled
Operating Mode:
Open Systems
Interop Mode:
Open Fabric 1.0
Active Domain Id:
1
World Wide Name:
10:00:08:00:88:00:21:07
show
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore director fc-64

Table of Contents