hardware powerup

Description of Command Function
Powers up the StoreOnce appliance. If a file server node is defined in the command entry, only
this node is powered up.
Command Syntax
hardware powerup [NODEX]
Command Authority
Administrator
Command Object Requirements
NODE X – As an option, this can be used to define an individual file server node. X is a unique
numeric index. NODEX is a label uniquely defining the hardware component; it was assigned
during the initial automatic hardware initialization and configuration and its value resides in the
"node_config" file. A complete list of the NODEX labels can be obtained using the hardware
show node status command (see
node is defined, only this node is powered up.
Command Parameter Requirements
Not applicable – no parameters exist within this command.
Requirements for Command Execution
The command entry must conform to the command syntax.
At least one system with an active CLI must exist.
If a file serving node is defined in the command entry, the defined node must be powered up.
Successful Command Output
Upon successfully sending the power up request, the following is displayed:
power up request successfully sent
NOTE:
This message only indicates the success for the power up request. The hardware show
node status command (see
that the server nodes powered up correctly.
Command Operation during Abnormal Conditions
If the command does not conform to the required syntax, the following is displayed:
Command Failed - the command does not conform to the required syntax,
SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this
section.
If the entire StoreOnce appliance or the specified node is already powered up, the following
is displayed:
Command Failed
Example
# hardware powerup node1
power up request successfully sent
26
Alphabetical List of Commands and Details
"hardware show node status" (page
"hardware show node status" (page
device already powered up
29)). If a file server
29)) must be entered to verify