Fibre Alliance MIB Objects
Note:
#2, and so on.)

connUnitSensorStatus

OID
Description
Note:

connUnitSensorInfo

OID
Description
Note:
Returns the serial ID if this is for the power supply. Otherwise, it returns Null.

connUnitSensorMessage

OID
Description
302
Each contains the name of sensor in textual format. (For example, Temp #1, Fan
1.3.6.1.3.94.1.8.1.4
The status indicated by the sensor. Possible values are:
unknown (1)
other (2)
ok (3):
warning (4):
failed (5):
Nominal = 3 (ok). Not nominal = 5 (failed).
1.3.6.1.3.94.1.8.1.5
Miscellaneous static information about the sensor such as its
serial number.
Each contains textual information about the sensor.
1.3.6.1.3.94.1.8.1.6
This describes the status of the sensor as a message. It may
also provide more resolution on the sensor indication, for
example, Cover temperature 1503K, above nominal operating
range.
The sensor indicates okay.
The sensor indicates a warning.
The sensor indicates failure.