Hp Tru64 Unix San Rules; Tru64 Unix San Configuration Rules - HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Reference Manual

San design
Hide thumbs Also See for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays:
Table of Contents

Advertisement

HP Tru64 UNIX SAN rules

This section describes the SAN rules for HP Tru64 UNIX.
For current storage system support, see the SPOCK website at http://www.hp.com/storage/spock.
You must sign up for an HP Passport to enable access.
Table 100
describes the SAN configuration rules for HP Tru64 UNIX.
for HP Tru64 UNIX multipathing coexistence.
Table 100 Tru64 UNIX SAN configuration rules
1
Storage systems
All supported
EVA3000
EVA6000
EVA4000
EVA6100
EVA4100
EVA8000
EVA5000
EVA8100
MSA1000
1
Unlisted but supported storage systems have no additional SAN configuration restrictions. For the latest support information, contact an
HP storage representative.
Zoning is required when Tru64 UNIX is used in a heterogeneous SAN with other operating systems.
Supports TruCluster Server.
Supports boot from SAN. For more information, see
and VA SAN boot
support" on page 268.
Supports multipathing high-availability configuration in multiple fabrics or in a single fabric with zoned
paths.
Zoning is required when a SAN is configured for multiple TruCluster products. Each TruCluster must
be in its own zone.
Supports connection of single HBA servers.
Supports active/active or active/passive failover mode.
A multipathing driver is embedded in the operating system.
For HP Continuous Access EVA configuration information, see
tegration" on page 254.
Requires a dedicated MSA1000.
Supports clusters with a maximum of 4 nodes.
Contact an HP storage representative for required operating system patches.
Table 101
Tru64 UNIX SAN rules
"EVA SAN boot
"HP Continuous Access EVA SAN in-
SAN Design Reference Guide
describes support
support" on page 256 and