To open the face panel:
1.
Open the disk drive bay door.
2.
Loosen the two thumbscrews that secure the face panel to the base unit (on the upper right and
upper left corners of the face panel). See the following figure.
3.
Pull the face panel toward you to open it. The face panel swings down on hinges attached to
the lower corners of the base unit. See the following figure.
To close the face panel:
1.
Lift the face panel upward and push it onto the base unit.
2.
Secure the face panel to the base unit by tightening the two thumbscrews.
3.
Close the disk drive bay door.
Closing the Base Unit
CAUTION
After servicing or upgrading the system, always replace the covers that were
removed. The covers ensure the system maintains proper air flow, so internal
components do not overheat and fail. The covers also ensure that electromagnetic
interference (EMI) emissions remain below the standard requirements.
To close the base unit:
1.
Remove the antistatic wrist strap from the base unit.
2.
Replace the top cover.
3.
Secure the top cover to the base unit with the screws retained earlier.
4.
Slide the base unit into the rack.
5.
Secure the base unit to the rack by replacing the screws attaching the handles to the rack.
6.
Reconnect all cables including the power cable, monitor, and peripheral cables to the back of
the system.