PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications

8.10.17 CF_STANDBYMODE Command

Command
"CF_STANDBYMODE_%1" [CR]
"ECO" ----------------------- Less standby electricity
%1
"NORMAL" -------------- Normal standby electricity
Switch Standby Mode setting.
Details
(Available in normal Power ON status only).
Acceptable
Response
Unacceptable

8.10.18 CF_ON-STA Command

Command
"CF_ON-STA_%1" [CR]
"ON" --------------------------- Set Power On Start to ON.
"OFF" ------------------------- Set Power On Start to OFF.
%1
"UP" ---------- Toggle between ON and OFF.(On→Off→On → - - -)
"DN" --------- Toggle between ON and OFF.(On→Off→On → - - -)
*"UP" and "DN" are exactly same operation.
Set/Cancel Power ON Start (Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.10.19 CF_POINTER Command

Command
"CF_POINTER_%1" [CR]
"ARROW" ---------------------- Select Arrow Pointer
%1
"FINGER" ---------------------- Select Finger Pointer
"LASER" ---------------------- Select Dot Pointer
Select indication of Pointer. (Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.10.20 CF_PTIMEMODE Command

Command
"CF_PTIMEMODE_%1" [CR]
"COUNTUP" ---------------------- Set P-timer to Count up mode
%1
"COUNTDN" ---------------------- Set P-timer to Count down mode
Select count up/down mode of P-timer.
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]