PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications
1. Overview
・ This Functional Specification defines communication with PJ-Net organizer for PLC-XM100 /
XM100L / XM150 / XM150L.
・ Supporting Firmware Ver. 1.x of the projector.
・ Commands in this document are to communicate with PJ-Net organizer, but most commands are
used to control a projector remotely from a computer with RS-232C. Therefore commands in this
document are defined as Expand Serial Commands.
2. Serial Interface Specification

2.1 Transfer Specification

Item
Synchronous System
Transmission Speed
Data Length
Parity
Stop Bit
Flow Control
Note1) Transmission Speed: initial setting value is 19200
Note2) Transmission Speed can be changed in Service mode.

2.2 Connection

Dedicated serial cables must be used for the connection between a computer and a projector.
Connect COM port of the computer to CONTROL PORT of the projector.
COM Port (COM1 or COM2) of a computer is specified by control software of the computer.
Asynchronous
9600 / 19200
8 bits
N/A
1
N/A
PC
COM 1
(D-Sub 9Pin)
9/79
Specification
Projector
CONTROL PORT
(D-Sub 9Pin)