PLC-WXU300 Expand Serial Command Functional Specifications
8.10.17 CF_PIPPOSITION Command
Command
"CF_PIPPOSITION_%1"[CR]
"BTMRIGHT" ----------------------- Move Subpicture to Bottom right
"BTMLEFT" ------------------------- Move Subpicture to Bottom left
"TOPRIGHT" ----------------------- Move Subpicture to Top right
"TOPLEFT" ------------------------- Move Subpicture to Top left
%1
"UP" ------------------------------ Switch Subpicture position forward
"DN" ------------------------------ Switch Subpicture position backward
Select Subpicture position of Picture in Picture.
This command is available in normal Power ON status.
Details
Note) Projector returns "101" by receiving this command when Picture in Picture is
Off.
Acceptable
Response
Unacceptable
8.10.18 CF_STANDBYMODE Command
Command
"CF_STANDBYMODE_%1"[CR]
"ECO" ---------------------- Less standby electricity
%1
"NORMAL" --------------- Normal standby electricity
Switch Standby Mode setting.
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.19 CF_P-MANE Command
Command
"CF_Pÿ MANE_%1"[CR]
"OFF" --------------------------------- Set Power Management to OFF
"READY" ----------------------------- Set Power Management to Ready
"SHUTDOWN" --------------------- Set Power Management to Shut Down mode
"UP" ------------------------------ Switch Power management setting
%1
"DN" ------------------------------ Switch Power management setting
Set/Cancel Power Management
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
ÿ Bottom right →Top right →Top left→Bottom left →
ÿ Bottom left →Top left →Top right →Bottom right→
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
ÿ Off → Ready → Shutdown → Offÿ
ÿ Off → Shutdown → Ready → Offÿ
"000"[CR]
"Error Code"[CR]
39/72