PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications
9.4.9 CR_WBAL-B Command
Command
"CR_WBAL-B" [CR]
Details
Get user controlled Blue value of White Balance
Acceptable
Response
%1
Unacceptable
9.4.10 CR_COLTEMP Command
Command
"CR_COLTEMP" [CR]
Details
Get Color Temperature setting status
Acceptable
Response
%1
Unacceptable
9.4.11 CR_OFFSET-R Command
Command
"CR_OFFSET-R" [CR]
Details
Get user controlled Red value of Offset
Acceptable
Response
%1
Unacceptable
9.4.12 CR_OFFSET-G Command
Command
"CR_OFFSET-G" [CR]
Details
Get user controlled Green value of Offset
Acceptable
Response
%1
Unacceptable
9.4.13 CR_OFFSET-B Command
Command
"CR_OFFSET-B" [CR]
Details
Get user controlled Blue value of Offset
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"000 – 063"
"Error Code" [CR]
"000_%1" [CR]
"000" --------------------------------- Xlow
"001" --------------------------------- Low
"002" --------------------------------- Mid
"003" --------------------------------- High
"BLANK" ---- OSD Menu is blank
(Neither of Xlow / Low / Mid / High)
"Error Code" [CR]
"000_%1" [CR]
"000 – 063"
"Error Code" [CR]
"000_%1" [CR]
"000 – 063"
"Error Code" [CR]
"000_%1" [CR]
"000 – 063"
"Error Code" [CR]
52/79