PLC-XL51 Expand Serial Command Functional Specifications

8.10.13 CF_STANDBYMODE Command

Command
"CF_STANDBYMODE_%1"[CR]
"ECO" ---------------------- Less standby electricity
%1
"NORMAL" ------- -------- Normal standby electricity
Switch Standby Mode setting.
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.14 CF_P-MANE Command

Command
"CF_Pÿ MANE_%1"[CR]
"OFF" --------------------------------- Set Power Management to OFF
"READY" ----------------------------- Set Power Management to Ready
"SHUTDOWN" --------------------- Set Power Management to Shut Down mode
"UP" ------------------------------ Switch Power management setting
%1
"DN" ------------------------------ Switch Power management setting
Set/Cancel Power Management
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.15 CF_P-MANETIME Command

Command
"CF_P-MANETIME_%1"[CR]
"01" ~ "30" ----------------------- Directly select setting time by the minute
"UP" ------------------------------- Plus one minute (01 → 02 → ÿ e ÿ e ÿ e → 30 → 01)
ÿ ÿ
"DN" ------------------------------- Minus one minute(30 → 29 → ÿ e ÿ e ÿ e → 01 → 30)
Set Power Management time
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.16 CF_ON-STA Command

Command
"CF_ONÿ STA_%1"[CR]
"ON" --------------------------- Set Power On Start to ON
"OFF" ------------------------- Set Power On Start to OFF
"UP" --------------------------- Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
%1
"DN" --------------------------- Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
Note) "UP" and "DN" behave the same.
Set/Cancel Power ON Start
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
ÿ Off → Ready → Shutdown → Offÿ
ÿ Off → Shutdown → Ready → Offÿ
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
33/63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xga ultra short-throw plc-xl51

Table of Contents