PLC-XD2200/2600
Expand Serial Command Functional Specifications
8.10.10 CF_CEIL Command
Command
"CF_CEIL_%1"[CR]
"ON" ------------------------ Set Ceiling to ON
%1
"OFF" ----------------------- Set Ceiling to OFF
Set/Cancel Ceiling setting.
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.11 CF_REAR Command
Command
"CF_REAR_%1"[CR]
"ON" --------------------------- Set Rear to ON
%1
"OFF" ------------------------- Set Rear to OFF
Set/Cancel Rear setting.
When Rear is ON, image is left/right reversed.
Details
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.12 CF_TERMINAL Command
Command
"CF_TERMINAL_%1"[CR]
"COMPUTER" ----------------Set Input mode
%1
"MONITOR" ------------------- Set Monitor Out mode
Set Terminal setup. This command is available in normal Power ON status.
Details
Terminal means Computer 2 in this model.
Acceptable
Response
Unacceptable
8.10.13 CF_STANDBYMODE Command
Command
"CF_STANDBYMODE_%1"[CR]
"ECO" ---------------------- Less standby electricity
%1
"NORMAL" ------- -------- Normal standby electricity
Switch Standby Mode setting.
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
When Input is Computer 2, the projector returns "101" and the
command is not executed.
"000"[CR]
"Error Code"[CR]
37 / 71