PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications

9.4.14 CR_NZRED Command

Command
"CR_NZRED" [CR]
Details
Get Noise Reduction setting status
Acceptable
Response
%1
Unacceptable

9.4.15 CR_PROGV Command

Command
"CR_PROGV" [CR]
Details
Get Progressive scan setting status
Acceptable
Response
%1
Unacceptable

9.4.16 CR_IMAGE Command

Command
"CR_IMAGE" [CR]
Details
Get image setting status
Acceptable
%1
Response
Unacceptable

9.4.17 CR_IMGGMD Command

Command
"CR_IMGGMD" [CR]
Details
Get setting status of Standard/Real/Cinema in Image Gamma
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"OFF" ----------------------------- Cancel Noise Reduction
"ON" --------------------------------Set Noise Reduction
"Error Code" [CR]
"000_%1" [CR]
"ON" ------------------------------ Set Progressive scan On
"FILM" ----------------------------- Select FILM mode
"OFF" ------------------------------ Set Progressive scan Off
"Error Code" [CR]
"000_%1" [CR]
"STAND" -------------------------------- Standard
"REAL" ------------------------------------ Real
"CINEMA" ---------------------------------- Cinema
"CUSTOM1" ------------------------------- "Image1"
"CUSTOM2" ------------------------------- "Image2"
"CUSTOM3" ------------------------------- "Image3"
"CUSTOM4" ------------------------------- "Image4"
"CUSTOM5" ------------------------------- "Image5"
"CUSTOM6" ------------------------------- "Image6"
"CUSTOM7" ------------------------------- "Image7"
"CUSTOM8" ------------------------------- "Image8"
"CUSTOM9" ------------------------------- "Image9"
"CUSTOM10" ----------------------------- "Image10"
"Error Code" [CR] ------------------------ When the command is
invalid due to condition such as Input source.
"?" [CR] --------------------------- When unknown command is
received
"000_%1" [CR]
"STD" -------------------------------- Standard
"REL" ------------------------------------ Real
"CNM" ---------------------------------- Cinema
"Error Code" [CR]
53/79