Cf_Disp Command; Cf_Backgnd Command - Sanyo PLC-XM100/L - 5000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XM100/L - 5000 Lumens:
Table of Contents

Advertisement

PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications

8.10.4 CF_DISP Command

Command
"CF_DISP_%1" [CR]
"ON" ----------------------------- Set Display to On
"CNTDWNOFF" --------------- Set Display to Count down Off
%1
"OFF" --------------------------- Set Display to Off
"UP" --------------- Switch forward (On → Count down Off → Off → On → ---)
"DN" --------------- Switch backward (On → Off → Count down Off → On → ---)
Set Display mode.(Available only in the normal Power ON status)
Details
The value set by this command is stored in EEPROM and setting remains effective
even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.10.5 CF_BACKGND Command

Command
"CF_BACKGND_%1" [CR]
"BLUE" -------------------- Select Blue Back
"USER" ------------------- Select User
%1
"BLACK" ------------------ Select Black Back
"UP" ---------- Switch forward (Blue Back→User→Black Back→Blue Back)
"DN" --------- Switch backward (Blue Back→Black Back→User→Blue Back)
Set Screen status for no signal.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Details
*When %1="USER" is received, error code "101" is returned, in the case of
Capture non-practice.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]