PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
8.10.27
CF_RSENS Command
Command
"CF_RSENS_%1" [CR]
"ALL" ----------------------------------- Select top, front and back receiver of projector
"FRONTTOP" ------------------------ Select front and top receivers of projector
"BACKTOP" -------------------------- Select only back and top receivers of projector
"FRONTBACK" ---------------------- Select only front and back receivers of projector
%1
"FRONT" ------------------------------ Select only front receiver of projector
"TOP" ---------------------------------- Select only top receiver of projector
"BACK" ---------------------------- Select only back receiver of projector
"UP" ---------- The same operation as pressing Up key or Left key
"DN" ----------The same operation as pressing Down key or Right key
Select location of infrared remote receiver of remote control
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.10.28
CF_P-MANE Command
Command
"CF_P-MANE_%1" [CR]
"OFF" ---------------------------------- Set Power Management to Off
"READY" ----------------------------- Set Power Management to Ready
%1
"SHUTDOWN" --------------------- Set Power Management to Shut Down mode
"UP" ---------- The same operation as pressing Up key or Left key
"DN" ----------The same operation as pressing Down key or Right key
Set/Cancel Power Management
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.10.29
CF_P-MANETIME Command
Command
"CF_P-MANETIME_%1" [CR]
"01" - "30" ----- Directly specify setting time by the minute
"UP" ------------ Increment value by 1 (Switched in 01→02→ --- → 30 → 01 order)
%1
"DN" ------------ Decrement value by 1 (Switched in 30→29→ --- → 01 → 30 order)
Set time of Power Management time
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.10.30
CF_STANDBYMODE Command
Command
"CF_STANDBYMODE_%1" [CR]
"ECO" ----------------------- Less standby electricity
%1
"NORMAL" -------------- Normal standby electricity
Details
Switch Standby Mode setting. (Available in normal Power ON status only).
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
48/89