PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications

9.6 Video Status Read Command

9.6.1 CR_SERSYS Command

Command
"CR_SERSYS" [CR]
Get selected current signal.
Auto detected signal is returned in Auto mode
Details
Only available when Input is Y,Pb/Cb,Pr/Cr, S-Video or Video. (This is not the case
for PC-Analog/PC-Digital/AV HDCP signals)
Acceptable
%1
Response
Unacceptable
"000_%1" [CR]
"1080PSF/24" ---------- 1080psf 24Hz
"1080P60" ------------- 1080p 60Hz
"1080P50" ------------- 1080p 50Hz
"1080P30" ------------- 1080p 30Hz
"1080P25" ------------- 1080p 25Hz
"1080P24" ------------- 1080p 24Hz
"1080I60" -------------- 1080i 60Hz , 1080psf 30Hz
"1080I50" -------------- 1080i 50Hz , 1080psf 25Hz
"1035I". ---------------- 1035i
"720P60" ------------------ 720p 60Hz
"720P50" ------------------ 720p 50Hz
"575P" ------------------ 575p
"480P" ------------------ 480p
"575I" ------------- 575i (includes Composite signal such as PAL)
"480I" ------------ 480i (includes Composite signal such as NTSC)
"NO_SIGNAL" --------------- No signal
*When 1080psf30 or 1080psf25 is inputted in System Auto,
parameter same as 1080i60/1080i50 is returned.
"101" [CR] --- When input signal is PC-Analog, PC-Digital or PC
signals in AV HDCP
"?" [CR]