Errors; Temperature Exceeded; Fan Failure - Smart Technologies SMART Board 600i3 Configuration And User's Manual

Interactive whiteboard system
Table of Contents

Advertisement

47 |
Message
Error (Temperature
Exceeded)
Error (Fan Failure)
Error (Color Wheel
Failure)
Error (Lamp Failure)

Errors

Temperature Exceeded

If the Temperature Exceeded indicator message appears and your projector turns off
during use, one of the following issues is occurring:
To resolve
1. Wait 15 minutes for the projector to cool down before attempting to restart.
the temperature
2. Make sure that nothing is blocking the air intake and exhaust.
exceeded error
3. Disconnect the power cord from the power outlet.
4. Reconnect the power cord.
5. If the previous steps don't resolve the issue and your projector still doesn't turn on,

Fan Failure

If the Fan Failure indicator message appears and your projector turns off during use,
one of the following issues is occurring:
To resolve your
Disconnect the power cord, and then contact your
fan failure error
CH A P T E R 6 – TR O U B L E S H O O T I N G Y O U R S M ART BOARD 60 0I 3 OR SBD 600 I3
I N T E R A C T I V E W H I T E B O A RD S Y S T E M
Your projector overheated internally. The projector can overheat because of
blocked air vents or an internal temperature over 131°F (55°C).
The temperature outside your projector is too high.
unplug the power cord, and then contact your
One of the fans has failed.
Your projector is overheating internally.
Power LED
(Green/Amber)
Off
Off
Off
Solid Amber
authorized SMART
authorized SMART
Temperature LED
(Red)
Flashing Red
Solid Red
Solid Red
Flashing Red
reseller.