Troubleshooting the EDA (Continued)
Table 8-1
Problem
EDA shuts off.
EDA is inactive.
Battery is not
inserted properly.
Battery is depleted.
Tapping the window
Screen is not
buttons or icons does
calibrated correctly.
not activate the
corresponding
feature.
The system is not
responding.
A message appears
Too many files
stating that the EDA
stored on the EDA.
memory is full.
Too many
applications
installed on the
EDA.
EDA keeps powering
The EDA's battery is
down to protect
low.
memory contents.
The radio is
powered on for a
long time.
Cause
The EDA turns off after a period of inactivity. If the EDA is
running on battery power, set this period from 1 to 5 minutes,
in one-minute intervals. If the EDA is running on external
power, set this period to 1, 2, 5, 10, 15, or 30 minutes.
Check the
Power
tab and tapping the
System
tab and change the setting for a longer delay before the
automatic shutoff feature activates.
Insert the battery properly. See
Main Battery on page
Replace the battery.
Re-calibrate the screen. See the MC70 User Guide.
Warm boot the system. See
Delete unused memos and records. If necessary, save these
records on the host computer (or use an SD card for additional
memory).
Remove unused installed applications from the EDA to
recover memory.
Select
Start
icon. Select the unused program and tap
Programs
Recharge the battery.
Because this mode requires battery power, power it off when
not needed. Using the SetDeviceState() API (refer to the
SMDK Help File), set the Bluetooth to D4 power state.
Maintenance and Troubleshooting
Solution
window by selecting
icon. Select the
Power
Installing and Removing the
1-3.
Resetting the EDA on page
>
>
tab and tap the
Settings
System
8 - 3
>
>
Start
Settings
Advanced
1-7.
Remove
.
Remove

Hide quick links: