Comtech EF Data SLM-5650 Installation And Operation Manual page 140

Satellite modem
Table of Contents

Advertisement

SLM-5650 Satellite Modem
Remote Control
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Rx Clock
RCI=
1 byte, value
Invert
of 0 or 1
Rx Data Invert
RDI=
1 byte, value
of 0 or 1
Rx Data Fault
RDF=
1 byte, value
of 0 thru 2
Rx BPSK
RBO=
1 byte, value
Data Ordering
of 0 or 1
Rx Demod
RSW=
8 bytes
Acquisition
Sweep Range
Description of Arguments
to Query
Command or Query.
Invert Receive Clock, where:
x=Invert Receive Clock, where:
0=Normal
1=Inverted
Example: RCI=1 (selects Inverted RX Clock)
Command or Query.
Invert Receive Data, where:
x=Invert Receive Data, where:
0=Normal
1=Inverted
Example: RDI=1 (selects Inverted RX Data)
Command or Query.
Receive Data Fault, where:
x= Receive Data Fault, where:
0=None
1=DATA
2=AIS
Example: RDF=0 (selects Data Fault = None)
Command or Query.
Invert Receive BPSK Data Ordering, where:
x=Invert Receive BPSK Data Ordering, where:
0=Normal
1=Inverted
Example: RBO=1 (selects Inverted BPSK Ordering)
Command or Query.
Rx acquisition sweep range of demodulator, in kHz, ranging from 0
to 60 kHz.
Example: RSW=0060.000 (selects 60 kHz)
Response to
Command
RCI =
RCI?
RCI*
RCI#
RDI =
RDI?
RDI*
RDI#
RDF =
RDF?
RDF*
RDF#
RBO =
RBO?
RBO*
RBO#
RSW=
RSW?
RSW*
RSW#
B–18
Revision 1
MN/SLM5650.IOM
Query
(Instruction
Response to Query
Code and
Qualifier)
RCI?
RCI=x
(see description of
arguments)
RDI?
RDI=x
(see description of
arguments)
RDF?
RDF=x
(see description of
arguments)
RBO?
RBO=x
(see description of
arguments)
RSW?
RSW=xxxx.xxx
(see description of
arguments)