3.5.4

Date and Time

If the DHCP server in your network provides the IP address of the SNTP server, no manual
configuration is necessary. If not, you have to set the SNTP IP address parameter manually.
For correct display of the current time, the Timezone offset must be set appropriately. This is
the time offset from UTC (Coordinated Universal Time). If, for instance, the phone is located in
Munich, Germany, the offset is +1 (or simply 1); if it is located in Los Angeles, USA, the offset
is -8. For countries or areas with half-our time zones, like South Australia or India, non-integer
values can be used, for example 10.5 for South Australia (UTC +10:30).
If the phone is located in a country with daylight saving, the administrator can choose whether
daylight saving time is activated manually or automatically. If Daylight saving is enabled, and
Auto time change is disabled, daylight saving time (DST) is in effect immediately. If Auto time
change is enabled, daylight saving is controlled by the Time zone parameter. This selects the
daylight saving time zone which is characterized by the start and end date for daylight saving
time.
The Difference (minutes) provides the time difference for daylight saving time in minutes. This
parameter is required also when Auto time change is enabled. In Germany, for instance, as
in most countries, this is +60.
3.5.4.1

SNTP is available, but no automatic configuration by DHCP server

Data required
SNTP IP address: IP address or hostname of the SNTP server.
Timezone offset (hours): Shift in hours corresponding to UTC.
Daylight saving: Enables or disables daylight saving time in conjunction with Auto time
change.
Value range: "Yes", "No"
Difference (minutes): Time difference when daylight saving time is in effect.
Auto time change / Auto DST: Enables or disables automatic control of daylight saving
time according to the Time zone.
Value range: "Yes", "No"
Time zone / DST zone: Area with common start and end date for daylight saving time.
Value range: "Australia 2007 (ACT, South Australia, Tasmania, Victoria)", "Australia 2007
(New South Wales)", "Australia (Western Australia)", "Australia 2008+ (ACT, New South
Wales, South Australia, Tasmania, Victoria)", "Brazil", "Canada", "Canada (Newfound-
land)", "Europe (Portugal, United Kingdom)", "Europe (Finland)", "Europe (Rest)", "Mexi-
co", "United States"
A31003-O1010-M100-17-76A9, 09/09/2010
OpenScape Voice - OpenStage Family, Administration Manual
administration.fm
Administration
System Settings
3-39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Openstage 60Openstage 80Openstage 20Openstage 15

Table of Contents