Qos Reports; Conditions And Thresholds For Report Generation - Siemens OpenStage 40 Administration Manual

Openscape voice
Hide thumbs Also See for OpenStage 40:
Table of Contents

Advertisement

3.24.9

QoS Reports

3.24.9.1

Conditions and Thresholds for Report Generation

For details about the functionality, please refer to the release notes.
>
The generation of QoS (Quality of Service) reports which are sent to a QCU server (see Section
3.3.8, "SNMP") is configured here.
Data required
Report mode: Sets the conditions for generating a QoS report.
Value range:
"OFF": No reports are generated.
"EOS Threshold exceeded": Default value. A report is created if a) a telephone con-
versation longer than the Minimum session length has just ended, and b) a threshold
value has been exceeded during the conversation.
"EOR Threshold exceeded": A report is created if a) the report interval has just passed,
and b) a threshold value has been exceeded during the observation interval.
"EOS (End of Session)": A report is created if a telephone conversation longer than
the Minimum session length has just ended.
"EOR (End of Report Interval)": A report is created if the report interval has just
passed.
Report interval (seconds): Time interval between the periodical observations.
Default: 60
Observation interval (seconds): During this time interval, the traffic is observed.
Value: 10
Minimum session length (100 millisecond units): When the Report mode is set to "EOS
Threshold exceeded" or "EOS (End of Session)", a report can be created only if the dura-
tion of the conversation exceeds this value.
Default: 20
Maximum jitter (milliseconds): When the jitter exceeds this value, a report is generated.
Default: 20
Average round trip delay (milliseconds): When the average round trip time exceeds this
value, a report is generated.
Default: 100
A31003-O1010-M100-17-76A9, 09/09/2010
OpenScape Voice - OpenStage Family, Administration Manual
administration.fm
Administration
Diagnostics
3-217

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Openstage 60Openstage 80Openstage 20Openstage 15

Table of Contents