Restoring The Factory Default Configuration - HP Model 745 - VME Workstation Owner's Manual

Model 745 industrial controller owner's guide
Hide thumbs Also See for Model 745 - VME Workstation:
Table of Contents

Advertisement

Restoring the Factory Default Configuration

To restore the factory default values in the EEPROM, follow the directions
in "Accessing the Boot Console Interface" earlier in this chapter, and then
type the following at the prompt to access the Configuration Menu:
Main Menu: Enter command > co
When the Configuration Menu appears, type the following at the prompt:
Configuration Menu: Enter command > default
The process takes less than 30 seconds and messages similar to the follow-
ing are displayed:
Initializing...
TEST 30CD
INIT 30CD
Configuration Menu: Enter command >
The factory default EEPROM settings are now restored.
The defaults are as follows:
OS_ID:
Fast Size:
Primary Path:
Alternate Path:
Console Path:
Keyboard Path:
Autoboot:
Autosearch
Autostart
The Boot Console Interface
Restoring the Factory Default Configuration
HP-UX
0xF (all memory is tested)
sescsi.6.0
sescsi.5.0
GRAPHICS(0) or PMCn where n is the lowest
numbered device installed. If no graphics
devices are installed this is set to SERIAL_1.
PS2
OFF
OFF
ON
B-11