Switch Fabric
Electrical
Specifications
Processor Module
Specifications
Extension Jack
Specifications
PAGE Jack
Specifications
MUSIC ON
HOLD Jack
Specifications
CONTACT
CLOSURE
Adjunct Jack
Specifications
SMDR Output
Format
Full digital, nonblocking
45 Watts (154 BTUs/hr.) per ACS processor module during normal power consumption
85 Watts (290 BTUs/hr.) per ACS processor module during maximum power consumption
10 Watts (35 BTUs/hr.) per 400 module, normal and maximum power consumption
35 Watts (120 BTUs/hr.) per 206 module during normal power consumption
75 Watts (256 BTUs/hr.) per 206 module during maximum power consumption
U.S., Canada, and other 110V countries:
ACS processor module and one 206 module (2-Slot carrier) = 2.3 Amps max. current, full
system capacity
ACS processor module and four 206 modules (5-Slot carrier) = 4 Amps max. current, full
system capacity
Countries using 220 V:
ACS processor module and one 206 module (2-Slot carrier) = 1.2 Amps max. current, full
system capacity
ACS processor module and four 206 modules (5-Slot carrier) = 2 Amps max. current, full
system capacity
45 days to 6 months memory backup with 2 AAA-size standard alkaline batteries (IEC LR03)
68306 16 Mhz processor
256Kbyte RAM
512Kbyte FLASH ROM
Custom VLSI DSP ASIC—16 bit, 52 Mhz
VLSI = Very Large Scale Integration
DSP = Digital Signal Processor
ASIC = Application Specific Integrated Circuit
Ringing voltage: +5VDC, –140 VDC peak to peak; trapezoidal wave shaping
35- to 38-Volt talk battery
Ringing frequency: 20 Hz
Draws current on inner wire pair
Provides paging contact closure on outer wire pair
600 Ohm impedance
Accepts 2 Volts at 50 Kohms maximum input
0 –18 dB attenuation
Operates up to 150 feet (45.72 meters) from control unit using 24 gauge solid conductor
wire if 2 Contact Closures used; up to 800 feet (243.84 meters) from control unit using 24
gauge solid conductor wire if only 1 Contact Closure used
Install the Contact Closure Adjunct in the same building as the control unit; cannot be
installed out-of-doors
Has three terminals per Contact Closure, providing a normally open and normally closed
function for each Contact Closure
Maximum contact voltages and current:
30 VAC, 1 Amp
50 VDC, 1 Amp
1200 baud
8 data bits
XON/XOFF protocol
Line feeds
No parity
2 stop bits
Carriage return
Specifications
35