Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide
Table 31: Site Electrical Wiring Guidelines (continued)
Site Wiring Factor
Electromagnetic compatibility
Related
Documentation

Environmental Requirements and Specifications for J-EX Series Switches

Table 32: J-EX Series Switch Environmental Tolerances
Description
Altitude
Relative humidity
Temperature
66
General Safety Guidelines and Warnings for J-EX Series Switches on page 201
General Electrical Safety Guidelines and Warnings for J-EX Series Switches on page 229
Prevention of Electrostatic Discharge Damage on J-EX Series Switches on page 230
AC Power Supply in a J-EX8200 Switch on page 39
The switch must be installed in a rack or cabinet housed in a dry, clean, well-ventilated,
and temperature-controlled environment.
Ensure that these environmental guidelines are followed:
The site must be as dust-free as possible, because dust can clog air intake vents and
filters, reducing the efficiency of the switch cooling system.
Maintain ambient airflow for normal switch operation. If the airflow is blocked or
restricted, or if the intake air is too warm, the switch might overheat, leading to the
switch temperature monitor shutting down the switch to protect the hardware
components.
Table 32 on page 66 provides the required environmental conditions for normal switch
operation.
Tolerance
No performance degradation to 10,000 feet (3048 meters)
Normal operation ensured in relative humidity range of 10% through
85%, noncondensing
Normal operation ensured in temperature range of 32° F through
104° F (0° C through 40° C)
Guidelines
If your site is susceptible to problems with electromagnetic
compatibility (EMC), particularly from lightning or radio
transmitters, seek expert advice.
Some of the problems caused by strong sources of
electromagnetic interference (EMI) are:
Destruction of the signal drivers and receivers in the switch
Electrical hazards as a result of power surges conducted
over the lines into the equipment