Mounting a J-EX8216 Switch on a Rack or Cabinet

108
Figure 42: Installing a Square-Hole Cage Nut
Position the power cord tray in the rack space immediately below the position where
4.
the switch is installed in a four-post rack (see Figure 43 on page 108). Line up the screw
holes of the power cord tray with the holes in the rack. Use 4 mounting screws
appropriate for your rack—plus washers if you installed cage nuts—to attach the power
cord tray to the rack.
Figure 43: Installing the Power Cord Tray in a Four-Post Rack
Mounting a J-EX8216 Switch on a Rack or Cabinet on page 108
The J-EX8216 switch ships installed with front-mounting brackets on the chassis for
mounting the switch on a 19-in. equipment rack or cabinet. (The remainder of this topic
uses "rack" to mean "rack or cabinet.") The switch also comes with adjustable mounting
brackets to support it in the rack.
In a four-post rack, the switch consumes 21 U without the optional power cord tray and
22 U with the optional power cord tray. Installation in a two-post rack is not supported.
You can mount two switches on a 42 U four-post rack provided that the rack meets the
strength requirements to support the combined weight of the switches.