Removing a Line Card from a J-EX8200 Switch

166
Grasp the handle on the faceplate of the SF module with one hand and pull the SF
6.
module to about halfway out.
Taking care not to touch the leads, pins, or solder connections, place one hand on the
7.
base of the SF module to support its weight, and slide it out of the chassis completely.
Place the SF module in the antistatic bag or on the antistatic mat.
8.
Figure 74: Removing an SF Module from a J-EX8216 Switch
Installing an SF Module in a J-EX8216 Switch on page 120
Switch Fabric (SF) Modules in a J-EX8216 Switch on page 29
J-EX8200 switches have field-replaceable unit (FRU) line cards that can be installed in
the line card slots on the front of the switch chassis. The line cards are hot-insertable
and hot-removable: You can remove and replace them without powering off the switch
or disrupting switch functions.
Before you begin removing a line card from a J-EX8200 switch:
Ensure that you have taken the necessary precautions to prevent ESD damage (see
"Prevention of Electrostatic Discharge Damage on J-EX Series Switches" on page 230).