112
Visually inspect the alignment of the switch. If the switch is installed properly in the
10.
rack, all the mounting screws on one side of the rack are aligned with the mounting
screws on the opposite side and the switch is level.
After ensuring that the switch is aligned properly, use the appropriate Phillips (+)
11.
screwdriver to tighten the screws to the rack posts.
CAUTION: To meet safety and electromagnetic interference (EMI)
requirements and to ensure proper operation, you must connect J-EX8200
switches to earth ground before you connect them to power. For installations
that require a separate grounding conductor to the chassis, use one of the
two protective earthing terminals on the switch chassis to connect to the
earth ground. For instructions on connecting a J-EX8200 switch to ground
using a separate grounding conductor, see "Connecting Earth Ground to a
J-EX Series Switch" on page 129.
Figure 47: Installing a J-EX8216 Switch in a Four-Post Rack
Removing a J-EX8216 Switch from a Rack or Cabinet on page 152
Connecting AC Power to a J-EX8200 Switch on page 131
Rack Requirements for a J-EX8216 Switch on page 69
Cabinet Requirements and Specifications for a J-EX8216 Switch on page 71