Image 11-7
About over-temperature protection
When the projector software detects a too high lamp temperature it automatically reduce the lamp power with 20%. This reduction
will be visible on the Lamp power menu.
It is possible to adjust the lamp power again to a higher value but the software will reduce the lamp power again if the temperature
is still to high.
At the same time, an message will be displayed on the LCD panel.
11.4 Lamp Identification
About
The lamp identification menu gives an overview of the most important parameters of the used lamps. It starts with the first lamp.
Scrolling to other lamps is possible with the cursor keys.
These parameters are:
Serial number lamp
Article number of the used lamp
Run time since first start up of the lamp
Remaining run time for a safe operation of the lamp
Number of strikes since the first start up of the lamp
Status of the lamp
These parameters are useful when calling for a service intervention.
How to display?
1. Press MENU to activate the menus.
2. Use the ▲ or ▼ key to select Lamp and press ENTER.
3. Use the ▲ or ▼ key to select Identification and press ENTER.
The identification overview is displayed.
4. Use the ◄ or ► key to select another lamp.
The status is given lamp per lamp. (image 11-8, image 11-9, image 11-10)
Image 11-8
R59770021 CLM R10+ 11/10/2010
Image 11-9
Image 11-10