Barco CLM R10+ R90501001 User Manual page 209

Hide thumbs Also See for CLM R10+ R90501001:
Table of Contents

Advertisement

Error
Description
code
7908
Fan inlet A low
7906
Fan inlet B low
7904
Fan lamp 1
back low
7902
Fan lamp 2
back low
7900
Fan lamp 3
back low
7899
Fan lamp 3
back high
7898
Fan lamp 4
back low
7896
Fan prism low
7894
Fan color
wheel low
7892
Fan lamp 1
front low
7890
Fan lamp 2
front low
7888
Fan lamp 3
front low
7886
Fan lamp 4
front low
7884
Pump speed
low
7883
Pump speed
high
7878
Over temp
7877
Under temp
7876
SMPS input
range
7875
DMD temp
open
7874
DMD temp
short
7873
Ambient temp
open
7872
Ambient temp
short
7871
TEC temp open
7870
TEC temp short
7865
Lamp 1 run
time msg
exceeded
7864
Lamp 1 run
time warning
exceeded
7863
Lamp 1 run
time max
exceeded
R59770021 CLM R10+ 11/10/2010
Error
Warning
Caused by
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
-
Yes
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Bad or no water flow in the cooling
circuit
-
Yes
Yes
Yes
extreme overheading of DMD or
lamps
DMD too cold
Supplied voltage is out of range
Yes
Yes
Sensor not connected
Yes
Yes
short circuit in sensor circuit
Yes
Yes
Sensor not connected
Yes
Yes
short circuit in sensor circuit
Yes
Yes
Sensor not connected
Yes
Yes
short circuit in sensor circuit
-
Yes
Run time of lamp 1 will be exceeded
-
Yes
Run time of lamp 1 is exceeded
-
Yes
The maximum run time for the lamp
is exceeded
E. Troubleshooting
Action
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
Ignore this message
If problem persists, call a qualified
service engineer
Warm up the projector
Check supplied voltage range
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
Replace the lamp with a new one.
Call a qualified service engineer
Replace the lamp with a new one.
Call a qualified service engineer
Replace the lamp with a new one.
Call a qualified service engineer
205