16. Servicing
Mercury Vapor Warnings: The lamp used in the projector contains mercury. In case of a lamp rupture, explosion there will be a
mercury vapor emission. In order to minimize the potential risk of inhaling mercury vapors:
Ensure the projector is installed only in ventilated rooms.
Replace the lamp module before the end of its operational life.
Promptly ventilate the room after a lamp rupture, explosion has occurred, evacuate the room (particularly in case of a pregnant
woman).
Seek medical attention if unusual health conditions occur after a lamp rupture, explosion, such as headache, fatigue, shortness
of breath, chest-tightening coughing or nausea.
Necessary tools
No tools.
How to remove a lamp
1. Switch off the projector and unplug the power cord from the wall outlet.
2. Remove the lamp door, see "Removal of the lamp door", page 182.
3. Unplug the cable of the lamp which must be removed. (image 16-7)
4. Pull up the fixation handle and rotate it fully upwards. (image 16-8)
5. Clasp the lamp and pull upwards. (image 16-9)
C
C
Image 16-7
Image 16-8
Lamp removal
174
C
C
R59770021 CLM R10+ 11/10/2010