5. Connections
The CLM R10+ is standard equipped with one 5 cable input module and one DVI input module.
5.3

Communication connections

Communication interface
A
STBY / ON
WARNING IR
B
C
OK
REC
D
10/100
ACT
E
F
10/100
BASE-T
G
USB
H
I
Image 5-10
Communication connections
A
Projector status LED
B
Warning LED
C
IR signal acknowledged LED
D
IR signal received LED
E
Ethernet port
F
DMX in port
G
DMX out port
H
USB port
I
RS232/422 output port
J
RS232/422 input port
K
XLR input port for remote control
L
IR receiver
M
Two digit 7-segment display for diagnostic code
Projector status
The projector "status" LED (A) lights up green while in operation. The same LED lights up red when the projector is switched to
standby.
Besides the projector status LED (A) the communication interface has also a "warning" LED (B) which blinks in case the projector
encounters an internal problem concerning fan speed, temperature, supply voltages, ... etc. These type of problems still allows
the projector to operate (the show can go on) but an action will be required within a short time period. More information about the
involved problem is given on the local LCD display of the projector.
A two character 7-segment display (M) shows, during normal operation, the selected input slot number. If an error has occurred
then an error code appears on this two digit display.
42
DIAGNOSTIC CODE
IR RECEIVER
1
3
IN
OUT
REMOTE
CTRL
DMX
RS232 / 422 OUT
RS232 / 422 IN
M
L
2
K
J
R59770021 CLM R10+ 11/10/2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clm r10+ r90501005Clm r10+ r9050100Clm r10+

Table of Contents