APRILIA RS 125 Workshop Manual page 183

Hide thumbs Also See for RS 125:
Table of Contents

Advertisement

RS125
24. PICK-UP SENSOR
Pick-up test
Disconnect the pick-up terminal connector.
Measure resistance across the yellow/white and
blue/violet wire terminals with a hand-held tester set to
the 1000 Ω scale: Resistance reading should be
between 190 and 300 Ω.
If resistance reading is outside the specified range,
change the pick-up.
25. WARNING HORN
Test voltage:
Current draw:
26. STARTER RELAY
Starter relay test
Check relay for correct operation as follows:
Feed 12 V to the two male terminals (85 -86).
Use a tester (placed in ohmmeter mode) to check
continuity across the other two terminals ( 87 - 30).
Correct reading with live relay: 0 Ω
Correct reading when relay is not fed:∞ Ω
If readings are not as specified, change the relay.
13 V (rated voltage 12 V)
< 3.5 A
ELECTRIC SYSTEM