ELECTRIC SYSTEM
WARNING
Cutting the jumper across the grey and red
wires of the Rave control unit will set solenoid
actuation threshold to 7,800 rpm.
•
Check that the piston moves freely.
•
Start the engine and keep it at idling speed.
•
Measure resistance across the wires using a tester:
Correct reading = 2.2 Ohm ± 10%.
Key:
1 – RAVE control unit
2 – RAVE solenoid
3 – Flywheel / regulator
•
Measure voltage across the solenoid wires with a
tester:
Correct reading = 11.5 ± 1 V at idling speed during a
one-second (only) pulse; after this initial pulse, reading
should stabilise at 5.5 ± 1 V D.C.
13. Safety diode
(stand, neutral, neutral light, starter relay)
Diode test
•
Disconnect the (white) two-way connector (4).
Check diodes for correct operation as follows:
7 - 8
RS125