Appendix A
Pager Code Server Event
range.
A fan sensor in the server has gone far outside the factory specified
004XX
range.
004XX
Fan sensor crossed lower non-recoverable threshold
Fan sensor crossed upper non-critical threshold
004XX
004XX
Fan sensor crossed upper critical threshold
004XX
Fan sensor crossed upper non-recoverable threshold
Two or more of the fans in the Processor/PCI Fan Tray have stopped
004XX
or have been removed.
004XX
Fan problem in Processor/PCI Fan Tray has been corrected.
Two or more of the fans in the Memory Fan Tray have stopped or
004XX
been removed.
Fan problem in the Memory Fan Tray has been corrected.
004XX
004XX
One of the fans in the Memory Fan Tray stopped.
004XX
One of the fans in the Processor/PCI fan tray stopped.
00520
I/O area open
00530
The server's built-in sensors have detected an open chassis door.
00530
Processor area open
00600
Front Panel Button Violation
Processor module is operating outside of acceptable margins
00701
00700
Processor internal error
Processor Thermal Trip Failure
00701
00702
Processor failed internal self test
00703
Processor hung during POST
00704
Processor startup/initialization failed
00705
Configuration Error in a Processor Slot
00707
Processor failure
00708
Processor (#) Disabled
Processor or Terminator was not detected
00709
00717
Processor problem
The Processor in the indicated slot has been disabled by the BIOS.
00718
00719
A single or multiple ECC Error has been detected on the P6 bus.
The Processor Card is missing or not properly terminated in indicated
00720
processor module.
Voltage Regulating Module (VRM) on the indicated processor
00721
module had failed.
Indicated Power Supply has been removed.
00800
00800
The indicated Power Supply has been inserted.
Power supply unit power has failed.
00801
00802
Predictive failure/alert in Power supply
00816
Redundant Power Supply: Subsystem warning temperature exceeded
00817
Temperature alert on designated Power Supply.
00818
Redundant Power Supply: AC power source failure
Redundant Power Supply: Protection temperature exceeded, DC
00819
shutdown
Redundant Power Supply: Protection temperature normal, power
00820
restored
00821
Fan failure on designated Power Supply.
00822
Fan speed-up on designated Power Supply.
78
Event Codes
Severity
CRITICAL
CRITICAL
WARNING
CRITICAL
CRITICAL
CRITICAL
INFORMATIONAL
CRITICAL
INFORMATIONAL
CRITICAL
CRITICAL
WARNING
WARNING
WARNING
INFORMATIONAL
WARNING
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
WARNING
WARNING
CRITICAL
WARNING
INFORMATIONAL
WARNING
WARNING
WARNING
CRITICAL
CRITICAL
CRITICAL
INFORMATIONAL
CRITICAL
WARNING