Replacing a System Fan

Caution: The system fans are NOT hot-swappable. Before removing or replacing a fan, you must
first take the server out of service, turn off all peripheral devices connected to the system,
turn off the system by pressing the power button, and unplug the AC power cord from the
system or wall outlet.
Note: The fans that are integrated into the power supply cannot be replaced separately. If one of
the fans in the power supply fails, the power supply must be replaced.
The system fans at the front of the Intel
replaced if one of them fails. Use the following steps to replace a dual rotor fan.
1. If installed, remove the PCI riser assembly. For instructions, see
PCI Riser Assembly" on page
2. If installed, remove the processor air duct. For instructions, see
Processor Air Duct" on page
3. Disconnect the fan cable from the backplane or fan board (see letter "A" in
Figure
4. Lift the failed fan from the module (see letter "B" in
5. Position the replacement fan so the connector on the fan is at the right and pointing
down.
6. With the fan oriented correctly, insert the fan into the fan module (see letter "A" in
Figure
fan board (see letter "B" in
®
Intel
Server System SR1600UR Service Guide
46.
83).
A

Figure 83. Removing a Fan from the Fan Module

84), and insert the fan cable into the matching connector on the backplane or
Figure
®
Server System SR1600UR can be individually
41.
Figure 83
84).
"Removing the
"Removing the
).
B
AF000368
93