58
IBM NetVista Type 6838, 6848: Hardware Maintenance Manual
Diagnostic Error Code
015-199-XXX USB port test failed, cause
unknown
018-000-XXX PCI Card Test Passed
018-0XX-XXX PCI Card Failure
018-195-XXX PCI Card Test aborted by user
018-196-XXX PCI Card test halt, error
threshold exceeded
018-197-XXX PCI Card test warning
018-198-XXX PCI Card test aborted
018-199-XXX PCI Card test failed, cause
unknown
018-250-XXX PCI Card Services error
020-000-XXX PCI Interface Test Passed
020-0XX-XXX PCI Interface error
020-195-XXX PCI Test aborted by user
020-196-XXX PCI test halt, error threshold
exceeded
FRU/Action
1. Go to the "Undetermined problems"
section
2. Flash the system and re-test
3. Replace component under function test
1. No action
1. Riser card, if installed
2. System board
1. PCI card
2. Information
3. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
1. Make sure the component that is called
out is connected and/or enabled
2. Flash the system and re-test
3. Go to the "Undetermined problems"
section
1. Go to the "Undetermined problems"
section
2. Flash the system and re-test
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
1. No action
1. PCI card
2. Riser card, if installed
3. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file