Diagnostic Error Code
014-199-XXX Parallel port test failed, cause
unknown
014-2XX-XXX 014-3XX-XXX Parallel port
failure
015-000-XXX USB port Interface Test Passed
015-001-XXX USB port Presence
015-002-XXX USB port Timeout
015-015-XXX USB port External Loopback
failure
015-027-XXX USB port Configuration/Setup
error
015-032-XXX USB port Device Controller
failure
015-034-XXX USB port buffer allocation
failure
015-035-XXX USB port Reset condition
detected
015-036-XXX USB port Register error
015-040-XXX USB port IRQ failure
015-195-XXX USB port Test aborted by user
015-196-XXX USB port test halt, error
threshold exceeded
015-197-XXX USB port test warning
015-198-XXX USB port test aborted
FRU/Action
1. Go to the "Undetermined problems"
section
2. Flash the system and re-test
3. Replace component under function test
1. External parallel device
2. System board
1. No action
1. Remove USB device(s) and re-test
2. System board
1. Remove USB device(s) and re-test
2. System board
1. Remove USB device(s) and re-test
2. System board
1. Flash the system
2. System board
1. System board
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
1. Remove USB device(s) and re-test
2. System board
1. System board
1. Run setup and check for conflicts
2. Flash the system
3. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the "Undetermined problems"
section
Chapter 7. Symptom-to-FRU index
57