Adding a data capture configuration

To add a data capture configuration to the Tech_Support_Center profile, enter the capture add
command, as shown in the following example. If the Tech_Support_Center profile does not exist, you must
create it using the profile create command.
8/20q FC Switch #> admin start
8/20q FC Switch (admin) #> callhome edit
8/20q FC Switch (admin-callhome) #> capture add
A list of attributes with formatting and default values will follow.
Enter a value or simply press the ENTER key to accept the default value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Value (press ENTER to accept the default, 'q' to quit):
TimeOfDay
DayOfWeek
Interval
A capture entry has been added to profile Tech_Support_Center.
This configuration must be saved with the 'callhome save' command
before it can take effect, or to discard this configuration
use the 'callhome cancel' command.

Modifying a data capture configuration

to modify a data capture configuration in the Tech_Support_Center profile, enter the capture edit
command, as shown in the following example:
8/20q FC Switch #> admin start
8/20q FC Switch (admin) #> callhome edit
8/20q FC Switch (admin-callhome) #> capture edit
Capture Entries for Profile:
Index
-----
1
Please select a capture entry from the list above ('q' to quit): 1
A list of attributes with formatting and current values will follow.
Enter a value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Value (press ENTER to accept the default, 'q' to quit):
TimeOfDay
DayOfWeek
Interval
The selected capture entry has been edited for profile Tech_Support_Center.
This configuration must be saved with the 'callhome save' command
before it can take effect, or to discard this configuration
use the 'callhome cancel' command.
118 Call Home configuration
(HH:MM)
(Sun,Mon,Tue,Wed,Thu,Fri,Sat)
(decimal value, 1-26 weeks)
TimeOfDay
DayOfWeek
---------
---------
02:00
Sat
(HH:MM)
(Sun,Mon,Tue,Wed,Thu,Fri,Sat)
(decimal value, 1-26 weeks)
[02:00]
[Sat
[1
Tech_Support_Center
Interval
--------
1 (weeks)
[02:00]
[Sat
[1
]
]
]
]