Verify Correct Operation Of System - HP A7990A - StorageWorks SAN Director 4/16 Blade Switch Hardware Reference Manual

Hp storageworks dc san backbone director hardware reference guide (5697-7346, september 2008)
Table of Contents

Advertisement

Verify correct operation of system

To verify that the DC Director is operating correctly:
1.
Log in to the DC Director as admin:
rsl8-st03-dcx-1:admin> login
login: admin
password: xxxxxxxx
rsl8-st03-dcx-1:admin>
2.
Type slotShow command and verify that all the installed cards are detected and that their status is
operational (enabled).
rsl8-st03-dcx-1:admin> slotShow
Slot
Blade Type
---------------------------------
1
UNKNOWN
2
UNKNOWN
3
SW BLADE
4
UNKNOWN
5
CORE BLADE 52
6
CP BLADE
7
CP BLADE
8
CORE BLADE 52
9
UNKNOWN
10
SW BLADE
11
UNKNOWN
12
UNKNOWN
rsl8-st03-dcx-1:admin>
3.
Verify that the DC Director is functioning correctly by typing switchShow or switchStatusShow.
94
Installing Field-replaceable units (FRUs)
ID
Status
VACANT
VACANT
55
ENABLED
VACANT
ENABLED
50
ENABLED
50
ENABLED
ENABLED
VACANT
51
ENABLED
VACANT
VACANT

Advertisement

Table of Contents
loading

Table of Contents