If not, POST is not complete or the CP blades have not achieved redundancy. Wait one or two minutes
and re-enter the command until you can verify that redundancy has been achieved.
4.
Type slotShow. The command output shows the new CP blade as "enabled":
swDir:admin> slotShow
Slot
Blade Type
---------------------------------
1
2
3
4
5
6
7
8
9
10
11
12
swDir:admin>
5.
Type firmwareShow to determine the Fabric OS version.
This example shows sample output for the firmwareShow command:
swDir:admin> firmwareShow
Local CP (Slot 7, CP1): Active
Remote CP (Slot 6, CP0): Standby
Note: If Local CP and Remote CP have different versions
of firmware, please retry firmwaredownload command.
swDir:admin>
6.
If the firmware version on the replacement blade does not match that on the active CP blade, bring the
replacement blade to the same firmware level as the active blade.
74
Installing Field-replaceable units (FRUs)
ID
Status
SW BLADE
16
SW BLADE
16
SW BLADE
16 ENABLED
SW BLADE
16
CR BLADE
17
CP BLADE
18 ENABLED
CP BLADE
18 ENABLED
CR BLADE
17 ENABLED
SW BLADE
16
SW BLADE
16 ENABLED
SW BLADE
16 ENABLED
SW BLADE
16 ENABLED
Primary partition:
Secondary Partition:
Primary partition:
Secondary Partition:
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
v6.0.0
v6.0.0
v6.0.0
v6.0.0