The slotShow command continues to show a faulty control processor (CP8), core switch (CR8), or
port blade even though the blade has been replaced.

Record critical DC Director and SAN information

All commands must be entered from a CLI session (Telnet or serial) to the active CP blade unless otherwise
indicated. For detailed information about Fabric OS commands, refer to the Fabric OS Reference Manual.
Use a checklist (<Link>Table 18) to ensure that all required information is recorded.
Table 18

Critical information checklist

Configuration information
Location of "config-switch.txt" file:
Location of "config-miscinfo.txt" file:
IP address, subnet mask:
WWN for DC Director:
SAN profile
Location of "SANbefor.txt" file:
Notes regarding nsshow output:
Notes regarding nsallshow output:
Notes regarding switchshow output:
Notes regarding fabricshow output:
Output from supportshow command
Location of "spptshow.txt" file:
Notes regarding supportshow output:
Information about the new chassis
New Factory Serial Num:
New Serial Num (if available):
To record critical DC Director and SAN information:
1.
Open a Telnet session and log in to the DC Director as admin. The default password is "password".
Enable the logging function on your Telnet or serial console connection.
2.
Back up the current configuration.
Type configUpload; then, enter the requested information at the prompts.
This command uploads the DC Director configuration to the customer-defined FTP server, making it
available for downloading. For more information about this command, refer to the Fabric OS
Command Reference.
rsl8-st03-dcx-1:admin> configupload
Protocol (scp or ftp) [ftp]: ftp
Server Name or IP Address [host]: 123.123.123.123
User Name [user]: Admin24
File Name [config.txt]: config-switch0.txt
Password:
Upload complete
rsl8-st03-dcx-1:admin>
3.
Record the DC Director values on a workstation
Record the WWN value: Type wwn; then, copy the command output into a file named
4.
"config-miscinfo.txt".
rsl8-st03-dcx-1:admin> wwn