6.
Type switchEnable to reenable the DC Director.

Verify the Port Identifier (PID) mode and connect to the fabric

Before connecting the DC Director to the fabric, verify that the port identifier (PID) mode on the DC Director
matches the other switches in the fabric. This parameter must be identical for all switches in the fabric and
is set using the configure command.
To connect the DC Director to the fabric:
1.
Add SFP optical transceivers (or XFP optical transceivers with FC10-6 port card installed) and cables to
the fibre channel ports.
The ports are color-coded to indicate which can be used in the same port group for trunking (trunking
port groups can be up to 8 ports). The ports and cables used in trunking groups must meet specific
requirements. Refer to the HP StorageWorks Fabric OS 6.x administrator guide.
2.
Position one of the optical transceivers so that the key is oriented correctly to the port. Insert the
transceiver into the port until it is firmly seated and the latching mechanism clicks.
Transceivers are keyed so that they can only be inserted with the correct orientation. If a transceiver
does not slide in easily, ensure that it is correctly oriented.
3.
Position a cable so that the key (the ridge on one side of the cable connector) is aligned with the slot in
the transceiver. Insert the cable into the transceiver until the latching mechanism clicks.
Cables are keyed so that they can be inserted in only one way. If a cable does not slide in easily,
ensure that it is correctly oriented.
4.
Repeat
step 1
5.
Organize the cables
6.
Verify DC Director and port status using the switchShow command.
7.
Verify fabric connectivity using the fabricShow command.

Enable software licenses

Depending on the model purchased, certain licenses are factory installed on the DC Director. To determine
which licenses are enabled, use the licenseShow command.
swDir:admin> licenseshow
AAbbccDDeeFFeeGG:
Web license
Zoning license
Extended Fabric license
Fabric Watch license
Performance Monitor license
Trunking license
Security license
In this example, the license key is AAbbccDDeeFFeeGG. Keep a copy of the license key for reference.
The 64-bit chassis ID is required to obtain and activate licenses for the DC Director. The chassis ID is
available through the licenseIdShow command. The licenseShow and licenseIdShow
commands must be typed through the active CP blade. Refer to the HP StorageWorks Fabric OS 6.x
administrator guide.
through
step 3
for the remaining ports.
("Managing
cables" on page 35).
DC SAN Backbone Director hardware reference guide