This switchShow command displays DC Director and port status information.
rsl8-st03-dcx-1:admin> switchshow
switchName:
switchType:
switchState:
switchMode:
switchRole:
switchDomain:
switchId:
switchWwn:
zoning:
switchBeacon:
blade3 Beacon:
blade5 Beacon:
blade8 Beacon:
blade10Beacon:
Index
Slot
===========================================================
32
3
33
3
34
3
35
3
36
3
10:00:00:00:c9:51:00:2d
37
3
rsl8-st03-dcx-1:admin>
4.
Verify that all the IP address information is correct by typing ipAddrShow and checking the results
against the IP information recorded in the "config-miscinfo.txt" file.
rsl8-st03-dcx-1:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin>
rsl8-st03-dcx-1
62.1
Online
Native
Subordinate
11
fffc0b
10:00:00:05:1e:39:59:67
OFF
OFF
OFF
OFF
OFF
OFF
Port
AddressMediaSpeedStateProto
0
0b2000idN4OnlineL-Port 5 public
1
0b2100__N8No_Module
2
0b2200__N8No_Module
3
0b2300__N8No_Module
4
0b2400idN4OnlineF-Port
5
0b2500__N8No_Module
DC SAN Backbone Director hardware reference guide
95

Advertisement

Table of Contents
loading