Check the connectivity between the Access Gateway N_Port and the fabric switch port.
Action
Severity
WARNING
AG-1008
Message
<timestamp>, [AG-1008], <sequence-number>,, WARNING, <system-name>, Invalid port
login (PLOGI) response from the fabric on the N_Port <port>.
Probable Cause
Indicates that the fabric switch management server did not accept the N_Port Login (PLOGI)
request sent by the Access Gateway.
Recommended
Please check the configuration of the fabric switch connected to the Access Gateway.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
AG-1009
Message
<timestamp>, [AG-1009], <sequence-number>,, WARNING, <system-name>, Sending FLOGI
failed on N_Port <port>.
Probable Cause
Failure sending Fabric Login (FLOGI) request from the Access Gateway to the fabric switch.
Recommended
Please check the configuration of the fabric switch connected to the Access Gateway.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
AG-1010
Message
<timestamp>, [AG-1010], <sequence-number>,, WARNING, <system-name>, Sending PLOGI
failed on N_Port <port>.
Probable Cause
Failure sending N_Port Login (PLOGI) request from the Access Gateway to the fabric switch.
Recommended
Please check the configuration of the fabric switch connected to the Access Gateway.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING