Bll-1000; Bll System Messages - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade error message reference guide v6.1.0 (53-1000600-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

BLL System Messages

BLL-1000

Message
<timestamp>, [BLL-1000], <sequence-number>, FFDC, CRITICAL, <system-name>, ASIC
driver detected Slot <slot number> port <port number> as faulty (reason: <reason>)
Probable Cause
Indicates that a blade regulation problem was reported on the specified slot number. The blade is
faulted.
The possible reason codes are as follows:
Recommended
Make sure that the blade is seated correctly.
Action
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems.
Refer to the Fabric OS Command Reference for more information on this command.
Fabric OS Message Reference
53-1000600-02
1 = Available buffer overflow
2 = Backend port buffer timeout
3 = Backend port got shut down
4 = Embedded port buffer timeout
5 = Excessive busy mini buffer
6 = Excessive RCC VC on E_Port
7 = Excessive RCC VC on FL_Port
8 = Fail detection buffer tag error
9 = Fail detection TX parity error
10 = EPI CMEM interrupt error
11 = CMI interrupt error
12 = Interrupt overrun
13 = FDET interrupt
14 = Interrupt suspended
15 = Filter LISTD error
16 = Unknown filter LIST error
17 = Wait for LPC open state
18 = Wait for Old port state
19 = Wait for Open init state
20 = TX parity error
21 = RAM parity error
22 = BISR or RAMINIT error