Fabr-1023; Fabr-1024; Fabr-1029 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade error message reference guide v6.1.0 (53-1000600-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

15

FABR-1023

Probable Cause
Indicates that the fabric size has exceeded the value-line limit, and the grace period counter has
started. If the grace period is complete and the size of the fabric is still outside the specified limit,
Web Tools is disabled.
Recommended
Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size
Action
of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a
full fabric license.
Severity
CRITICAL
FABR-1023
Message
<timestamp>, [FABR-1023], <sequence-number>,, INFO, <system-name>, Fabric size is
within supported configuration (<supporteddomains>). Fabric limit timer (<type>)
stopped at <grace period in seconds>.
Probable Cause
Indicates that the fabric size is within specified limits. Either a full fabric license was added or the
size of the fabric was changed to within the licensed limit.
Recommended
No action is required.
Action
Severity
INFO

FABR-1024

Message
<timestamp>, [FABR-1024], <sequence-number>,, INFO, <system-name>, Initializing
fabric size limit timer <grace period>
Probable Cause
Indicates that the fabric size has exceeded the limit set by your value-line switches. Value-line
switches have a limited fabric size: a specified limit to the number of domains. This value is defined
by your specific value-line license key. The fabric size has exceeded this specified limit. The
grace-period timer has been initialized. If the grace period is complete and the size of the fabric is
still outside the specified limit, Web Tools is disabled.
Recommended
Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size
Action
of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a
full fabric license.
Severity
INFO

FABR-1029

Message
<timestamp>, [FABR-1029], <sequence-number>,, INFO, <system-name>, Port <port
number> negotiated <flow control mode description> (mode = <received flow control
mode>).
Probable Cause
Indicates that a different flow control mode, as described in the message, is negotiated with the
port at the other end of the link. The flow control is a mechanism of throttling the transmitter port
to avoid buffer overrun at the receiving port. There are three types of flow control modes:
106
Fabric OS Message Reference
53-1000600-02